Loading...

V Series - VXT/VT0/VT1

Open Cooling Towers

Australia's leading Cooling Tower manufacturer! BAC Australia' s Series V, VTO, VT1 Open Cooling Towers are a proven cost-effective method of cooling condenser water loops and industrial processes.

Enquire Now

Local Standards Compliance

AS/NZS:3666 Microbial Control Standards

This standard covers various aspects of the design, installation, commissioning, cleaning, operation and maintenance of air conditioning systems including cooling water systems. All aspects of the standard are applicable for evaporative equipment. It is imperative that the equipment you buy is designed or modified to meet local standards. Beware that most imported product does not comply which may leave designers, contractors and owners vulnerable to risk of prosecution in the case of micro-biological outbreak.

AS/NZS:4024 Safety of Machinery Standards

This standard provides designers, manufacturers, contractors and owner/operators of machinery with requirements to reduce the risks of working with, or near, machinery. In particular, this standard is applicable to ingress of equipment via access and guarding requirements. Beware that most imported product does not comply which may leave designers, contractors and owners vulnerable to risk of prosecution in the case of accident.

AS/NZS:1657 Fixed platforms, walkways, stairways and ladders

This standard identifies the minimum requirements for fixed platforms, walkways, stairways and ladders - Design, construction and installation. It is important to to understand that imported equipment seldom meets this standard which is dimensionally product and site specific. The absence of compliant access may impede inspection, monitoring and maintenance of equipment, while non-compliant access may impede or impact site safety.

AS/NZS MEPS Standard Compliance

Minimum Energy Performance Standards (MEPS) standards specify the minimum level of energy performance that electrical equipment (products) must meet or exceed before they can be offered for sale or used for commercial purposes in Australia.

Features & Benefits

Loading...

Series V Cooling Tower

The Series V Cooling Tower is an ideal like-for-like replacement unit for many existing applications, offering the lowest replacement cost with no structural, electrical or piping modifications. It can overcome high external static pressure and has low sound capabilities which makes it a great fit for indoor applications and for ducted and sound sensitive locations.

  • Thermal Capacity: 12 - 1,335 tons1
  • Flow Rate: Up to 6,750 USGPM1
  • Counterflow // Centrifugal Fan // Forced Draft
Loading...

Increased Installation and Application Flexibility

  • Centrifugal fans that can overcome the static pressure imposed by external ductwork, allowing the Series V to be installed indoors
  • Well-suited for height sensitive installations with low profile models as short as 5’-2”
  • Low installed cost for replacement units since all models mount directly on two parallel I-beams
Loading...

Lowest Sound

  • One of the lowest sound cooling towers available, centrifugal fans have inherently low sound characteristics
  • With the single side air inlet, sound-sensitive areas can be addressed by facing the quiet blank-off panel to the sound-sensitive direction
  • For extremely sound sensitive applications, factory designed tested/rated sound attenuation is available for both the air intake and discharge
Loading...

  • Key components including motors, drives, and bearings are protected from moisture and condensation since they are located in the dry airstream
  • Complies with local codes including AS/NZS 3666 Microbiological, AS/NZS 4024 Guarding and AS/NZS 1657 Access.
Loading...

100% Thermal Performance

All standard VT0/VT1 Series models are certified by the Cooling Technology Institute (CTI) which require strict CTI testing procedures ensure that towers are 100% of documented thermal performance when installed and maintained correctly.

CTI Certification (not just CTI membership) is your insurance policy to ensure you get what you paid for when you need it.
BAC is your thermal integrity partner, Because Temperature Matters.

Recent Projects

Loading...
Loading...
Loading...
Loading...
Loading...
Loading...

Upgrade & Refurbishment

Loading...

VXT/VT0/VT1 Upgrades and Refurbishment


Reimagine your current equipment to meet all your future needs. BAC has unmatched experience of providing specialized engineered solutions to address even the most extreme challenges. Be sure to investigate all potential options before replacing your existing equipment.

Genuine Parts

Loading...

VXT/VT1/VT0 Genuine Parts - The Perfect Fit

BAC Parts Map is a comprehensive document identifying parts which are crucial to the ongoing operational and thermal integrity of your equipment. Bes sure to call the experts for your BAC parts solution because temperature matters to you.

Key Resources

Find an expert

Need some help?

If you could use some help finding the ideal cooling system for your next project please contact one of our cooling experts.

Find an Expert