CXV 1 2 3 4 5 6 7 8 9 10
  • 1

    Low kW Axial Fan

    • Quiet operation.
    • Corrosion resistant aluminum.
  • 2

    Fan Drive System

    Premium quality belts. Corrosion resistant sheaves. Heavy-duty bearings. Adapted fan motor for operation in saturated conditions.
  • 3

    Heavy Duty Construction

    ZAM coated steel panels.
  • 4

    Hinged Access Doors

    Inward swinging door.
  • 5

    Recirculating Spray Water Pump

    • Close coupled, bronze fitted centrifugal pump.
    • Totally enclosed fan cooled (TEFC) motor.
    • Bleed line with metering valve installed from pump discharge to overflow.
  • 6

    * BACross Wet Deck Surface with Integral Drift Eliminators (Not Shown)

    Plastic material. Impervious to rot, decay and biological attack. Designed and manufactured by BAC.
  • 7

    Cold Water Basin

    • Sloped water basin for easy cleaning.
    • Suction strainer with anti-vortex hood.
    • Adjustable Water make-up assembly with air inlet side.
    • Integral internal walkway as standard.
  • 8

    Combined Inlet Shield Technology

    • Corrosion resistant.
    • Easily removable.
    • UV resistant plastic material.
  • 9

    *Coil (Not Shown)

    Available in either hot-dip galvanised steel or stainless steel.Designed in accordance with AS2971 and manufactured within an ISO:9001 certified Quality Assurance ProgramEach coil is pressure tested to 2750 kPa after fabrication
  • 10

    Water Distribution System

    • Visible and accessible during operation.
    • Overlapping spray patterns ensure proper water coverage.
    • Large orifice, non-clog nozzles.

Series 1500 CXV

Evaporative Condensers

Key Features

  • Combined Flow Technology
  • Multiple Fan Construction
  • Full Internal Access

Key Benefits

  • Reduced energy consumption
  • Easy Access for Maintenance
  • Reduced Refrigerant Charge

Characteristics

Combined flow, Axial Fan, Induced Draft

Key Features

Combined Flow Technology

BAC’s range of combined flow units, utilise the best in both worlds. By cooling through direct evaporation onto the coil surface as well as through a fill material, before being recirculated back to the sprays.

Multiple Fan Construction

Multiple fans provide redundancy as well as energy efficiency when working on VSD based controls.

Full Internal Access

Open internal area provided for ease of access to all components within the unit for maintenance.

Key Benefits

Reduced Energy Consumption

High efficiency electrical equipment options as standard provide for a high level of energy efficiency for kW of heat rejected compared to other products.

Easy Access for Maintenance

Spacious Interior - Provides easy access to the cold water basin, drift eliminators, fan drive system and heat transfer coil.

Reduced Refrigerant Charge

High efficiency coil design and BAC Combined Flow Technology allow for a small coil size. This equates to a smaller refrigerant charge in the condenser and in turn the whole system.

Principle of Operation

CXV Principle of Operation

The CXVE combines the use of an evaporative condensing coil with an intergrated fill pack for cooling down the recirculating spray water.
The vapour (1) circulates through a condensing coil (2), which is wetted by a spray system (3). In parallel with the water spray flow, an axial fan (4) draws air (5) over the coil. The evaporation process condenses the vapour into liquid (6). The spray water falls onto a fill pack (7) where it is cooled before falling into the sloping water basin (8) or sump. The spray pump (9) recirculates the cooled water to the top of the unit. The warm saturated air (10) leaves the tower through the drift eliminators (11) which remove water droplets from the air.